Ground Lock Operating Instructions |
|
|
To Secure Aircraft:
- Ensure aircraft electrical system is denergized.
- Detach the battery connector from the aircraft battery by rotating the quick disconnect in a counterclockwise direction until separation occurs.
- Mate the battery connector to the ground lock and secure it by rotating the quick disconnect in a clockwise direction until it stops.
- Rotate key in a clockwise direction until it stops and remove the key.
To Restore Aircraft:
- Ensure aircraft electrical system is denergized and the battery master is off.
- Insert key into the ground lock and rotate counterclockwise until it stops.
- Detach the battery connector from the ground lock by rotating the quick disconnect in a counterclockwise direction until separation occurs.
- Mate the battery connector to the aircraft battery and secure it by rotating the quick disconnect firmly in a clockwise direction until a positive stop is felt.
|
|
|
|